Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
J Clin Exp Dent ; 15(11): e904-e911, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38074168

RESUMO

Background: This paper analyses the effects of root canal fragility and irrigation on external temperature change (ΔT) of different sections of roots during post-space preparation. Material and Methods: Forty endodontic treated human premolars were evaluated. Roots were divided into four groups based on their root wall thickness (fragile or non-fragile), and whether they received irrigation (yes or no) during post-space preparation. Initial root canal temperature was kept at 37°C. ∆T was evaluated with thermistors attached to the cervical and apical thirds of the roots during two preparation steps: 1) removal of gutta-percha with Largo drills, and 2) using the specific drill for post-space preparation for cementation of fiber-reinforced posts. In the irrigated groups, we used a 2% chlorhexidine solution during the exchange of drills. ∆T data was analyzed using four-way ANOVA with repeated measures and Tukey's test (α = 0.05). Results: Significant differences in ∆T based on root fragility (p = 0.017), root canal third (p = 0.013), and preparation step (p = 0.006). We found that non-fragile roots tended to have higher ∆T than fragile roots, particularly in the apical third, during the use of the second drill. Irrigation did not have a significant effect on temperature variation, regardless of root wall thickness or the third evaluated (p> 0.05). Conclusions: Findings suggest that root wall thickness and the third evaluated influence temperature changes during post-space preparation for cementation of posts. Non-fragile roots showed greater temperature variation than fragile roots, while irrigation did not significantly impact temperature changes. Key words:Temperature, post and core technique, tooth preparation.

2.
Gen Dent ; 71(5): 53-57, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37595084

RESUMO

Determining the appropriate technique for diastema closure is challenging, and the decision must be evidence based. The objective of these case reports is to describe different approaches to diastema closure using direct and indirect techniques, focusing on the characteristics of the patient and clinical requirements to guide treatment. In the first case, a 16-year-old patient had multiple diastemas in the maxillary anterior dentition. The clinical evaluation revealed microdontia of the lateral incisors and malpositioned teeth. The treatment included tooth whitening and placement of composite resin veneers using a direct technique. In the second case, a 54-year-old patient displayed a disharmonious and esthetically compromised smile due to small teeth, color changes, multiple diastemas, incisal wear, and severe dentogingival disproportion. Based on the patient's expectations, the patient's age, and the presence of a "black triangle" interdental space, a multidisciplinary restorative treatment was proposed, including gingivoplasty, tooth whitening, and placement of ceramic laminate veneers using an indirect technique. Both approaches achieved successful esthetic rehabilitation and diastema closure with minimal intervention. The choice of procedure and restorative material, as well as the need for tooth preparation, varied based on the clinical requirements, patient expectations, and financial constraints. Careful treatment planning avoided lengthy and inefficient procedures.


Assuntos
Diastema , Má Oclusão , Humanos , Adolescente , Pessoa de Meia-Idade , Diastema/terapia , Estética Dentária , Facetas Dentárias , Cerâmica , Resinas Compostas/uso terapêutico
3.
J Esthet Restor Dent ; 35(3): 442-448, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36161755

RESUMO

OBJECTIVE: This case report described the use of a stamping technique associated with a bulk fill composite to restore an ICDAS 4 carious lesion on a posterior tooth. The 4-year follow-up is also presented. CLINICAL CONSIDERATIONS: A 32-year-old patient presented a carious lesion on tooth 36 with an underlying dark shadow at the dentin seen from the noncavitated enamel occlusal surface, which was compatible with an ICDAS 4 carious lesion. The lesion was radiographically detected and the caries disease was treated with dietary and hygiene habits orientations. Before accessing the lesion and selectively removing the carious tissue, an occlusal stamp was made by applying a flowable resin composite to copy the anatomy of the noncavitated enamel surface. The cavity was restored using a bulk fill resin composite (Opus Bulk Fill, FGM) with 4-mm-thick increments. Before curing the last increment, a Teflon band was adapted at the uncured bulk fill composite surface and the occlusal stamp made with the flowable composite was pressed against it to reproduce the natural characteristics and initial occlusal anatomy. The top surface was light-activated for 40 s. After 4 years, small wear could be seen in the restoration, but still within clinically acceptable levels. CONCLUSION: The occlusal stamp technique allows reproduction of the natural anatomy of teeth affected by ICDAS 4 carious lesions with good clinical longevity over 4 years. CLINICAL SIGNIFICANCE: This case report presents the use of the stamp technique to restore a tooth affected by an ICDAS 4 lesion, in which a carious process reached the dentin and the enamel anatomy was still preserved. The bulk fill resin composite associated with the occlusal stamp was chosen to quickly restore the cavity with clinical predictability. Bulk fill composites allow the insertion of up to 4-mm-thick increments and offer lower shrinkage stress, good clinical longevity and a less time-consuming procedure in cases of posterior teeth, especially if associated with the stamp technique.


Assuntos
Cárie Dentária , Humanos , Adulto , Seguimentos , Cárie Dentária/terapia , Esmalte Dentário , Resinas Compostas , Restauração Dentária Permanente
4.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1523860

RESUMO

Objective: The aim of this in vitro study w as t o analyze the influence of the titanium dioxide nanotubes i n a self-cure mode polymerization of a dual resin luting agent through push out bond strength and radiopacity tests. Material and Methods: After mixed with a commercial du al self-adhesive resin cement, three concentrations o f tit anium dioxide nanotubes (0.3, 0.6, and 0.9% by weight) we re analyzed in self-curing mode. T he bond strength to bovine root dentin and fi berglass posts was assessed with the push out bond str ength t est and was evaluated in three thirds (cervical, middle and apical) (n=10), followed by failure mode analysis (SEM), and the ISO standard 9917-2 was followed for radiopacity test (n=10). Data were statistically analyzed by one-way ANOVA test, followed by Tukey's test (α=0.05). Results: Reinforced self-adhesive resin cement with 0.6% titanium dioxide nanotubes showed significant difference compared to the control gr oup for push out test (p=0.00158). The modified groups did not s how significant difference among thirds (p=0.782). Radiopacity sh owed higher value for group w ith 0.9% titanium dioxide nanotubes in comparison w ith control group (p<0.001). Conclusion: The addition of titanium dioxide nanotubes to a self-adhesive resin cement increased the bond strength to dentin and radiopacity values in the self-cure polymerization mode (AU)


Objetivo: O objetivo deste estudo in vitro foi analisar a influência de nanotubos de dióxido de titânio na polimerização química de um agente cimentante resinoso dual através de testes de resistência à união e radiopacidade. Material e Métodos: Após misturado com um cimento resinoso auto-adesivo comercial, três concentrações de nanotubos de dióxido de titânio (0,3, 0,6 e 0,9% em peso) foram analisadas. A resistência da união para a dentina da raiz bovina e os pinos de fibra de vidro foi avaliada pelo teste de push-out e avaliada em três terços (cervical, médio e apical) (n = 10), seguido pelo análise de modo de falha (MEV) e a norma ISO 9917-2 foi seguido para teste de radiopacidade (n = 10). Os dados foram analisados estatisticamente pelo teste ANOVA um fator seguido do teste de Tukey (α = 0,05). Resultados: O cimento resinoso auto-adesivo reforçado com nanotubos de dióxido de titânio a 0,6% mostrou diferença significativa em comparação com o grupo controle para teste de push-out (p=0,00158). Os grupos modificados não mostraram diferença significativa entre os terços (p=0,782). A radiopacidade mostrou maior valor para o grupo com nanotubos de dióxido de titânio 0,9% em comparação com o grupo controle (p<0,001). Conclusão: A adição de nanotubos de dióxido de titânio a um cimento resinoso auto-adesivo aumentou a os valores de resistência de união à dentina e radiopacidade no modo de polimerização química do agente cimentante (AU)


Assuntos
Titânio , Cimentos Dentários , Pinos Dentários , Nanotubos
5.
Dent Mater ; 38(8): e220-e230, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35750506

RESUMO

OBJECTIVE: This study evaluated the microshear bond strength of a resin cement to Y-TZP after different methods of TiO2 nanotubes (nTiO2) incorporation on pre-sintered Y-TZP surfaces. METHODS: nTiO2 were synthesized and incorporated on Y-TZP slices as follows (n = 15): 1) nTiO2 mixed with isopropyl alcohol/manual application (MAl); 2) nTiO2 mixed with acetone/manual application (MAc); 3) nTiO2 mixed with isopropyl alcohol/high-pressure vacuum application (HPVAl); 4) nTiO2 mixed with acetone/high-pressure vacuum application (HPVAc). As controls, surfaces were sandblasted with Al2O3 (OX) or Rocatec silicatization (ROC). All ceramics were sintered after nTiO2 incorporation. Surface treatments of OX and ROC were made after sintering. Surfaces were characterized by confocal laser microscopy, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Resin composite cylinders (1.40 mm diameter and 1 mm height) were cemented with a resin cement, stored in water at 37 °C for 24 h and thermocycled for 10 000 cycles before microshear bond strength evaluation. Data were analyzed with one-way ANOVA and Games-Howell (α = 0.05), and fracture analysis was performed using a stereomicroscope. RESULTS: EDS confirmed the presence of TiO2 on treated Y-TZP. The confocal analysis showed higher roughness for HPVAc and OX. There were significant differences between surface treatments (p < 0.001). HPVAl (22.96 ± 10.3), OX (34.16 ± 7.9) and ROC (27.71 ± 9.4) showed higher microshear bond strengths and were statistically similar (p > 0.05). MAC showed intermediary values, and HPVAc and MAl presented decreased bond strength, with a high percentage of premature debonding. CONCLUSION: High-pressure vacuum application of nTiO2 mixed with isopropyl alcohol was able to produce bond strength values compared to conventional air abrasion and Rocatec silicatization. SIGNIFICANCE: The infiltration of TiO2 nanostructures on the pre-sintered Y-TZP is an interesting approach that can improve bond strength without the need of sandblasting methods.


Assuntos
Colagem Dentária , Nanotubos , 2-Propanol , Acetona , Abrasão Dental por Ar , Colagem Dentária/métodos , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Resistência ao Cisalhamento , Propriedades de Superfície , Titânio , Ítrio/química , Zircônio/química
6.
Biomater Investig Dent ; 9(1): 20-32, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35528027

RESUMO

Introduction: Bonding to crystalline zirconia is currently a challenge. Properly cured adhesives are crucial to optimize this bond, and that in turn is influenced by the initial mobility of the system, as well as by the reactivity of the initiators. Aim: This study aimed to characterize adhesives containing monomer mixtures of different viscosities and double and triple photoinitiator systems; and to evaluate the bonding to Y-TZP zirconia, when adhesives were light-activated with monowave or polywave light-curing units (LCU). Materials and methods: Adhesives were formulated at a 1:1 weight proportion of Bis-GMA/TEGDMA or Bis-GMA/Bis-EMA. To these mixtures 0.5 wt% of CQ, 0.5-1.0 wt% of DABE, 0.5-1.0 wt% of DPIHP, or 0.5-1.0 wt% of TAS-Sb were added and used as photoinitiator systems. A total of ten adhesives were prepared. Resin composite cylinders were cemented on zirconia slices and 6000 thermal cycles were performed. Degree of conversion (DC), sorption (SO) and solubility (SL) after 7 days of water storage, and microshear bond strength (µSBS) were evaluated. Data were analyzed with three-way ANOVA and Tukey's HSD (α = 0.05). Results: Bis-GMA/Bis-EMA combined with either CQ/DABE or CQ/DABE/TAS-Sb presented the highest DC, and no significant differences were observed for LCUs (p = .298). CQ/DABE < CQ/DABE/TAS-Sb ≈ CQ/DABE/DPIHP and the polywave LCU showed smaller overall SO (p < .05). Bis-GMA/TEGDMA with CQ/DABE cured with the polywave LCU presented the lowest SO. SL varied as follows: CQ/DABE/TAS-Sb < CQ/DABE/DPIHP < CQ/DABE (p < .001). For µSBS, only the factor photoinitiator system was significant (p = .045). All mean values were above 30 MPa, with higher values being observed for BIS-GMA/TEGDMA and CQ/DABE. Conclusion: It can be concluded that the adhesive containing CQ/DABE/TAS-Sb as coinitiator of Bis-GMA/Bis-EMA mixtures produced a material with higher DC and lower SL, while bond strength values were similar to the ones obtained by CQ/DABE.

7.
J Clin Exp Dent ; 14(2): e168-e176, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35173900

RESUMO

BACKGROUND: Provisional materials must have enough strength to withstand masticatory loads without suffering deformation or fracture, and their surfaces must have good finishing and polishing characteristics to reduce biofilm accumulation. Thus, the purpose of this study was to investigate the best polishing protocol for different bis-acryl composite resins in comparison with a conventional resin composite and a self-curing acrylic resin aiming to obtain a smooth restoration surface and resistance to wear. MATERIAL AND METHODS: One hundred and four samples (15 mm length x 5 mm width x 4 mm depth) were prepared and divided into four groups according to the material tested: Protemp 4 and Structur 3 bis-acryl composite resins, Dencor self-curing acrylic resin, Filtek Z350XT conventional composite resin. The polishing procedures were performed with Sof-Lex Pop-On discs or Sof-Lex spirals and abrasion procedures were performed on a brushing machine. The surface roughness was analyzed at three periods (initial, post-polishing and post-brushing) and the wear was evaluated after simulated brushing. The results were submitted to ANOVA followed by the Tukey (α = 0.05). RESULTS: Filtek Z350XT groups showed the lowest values of initial surface roughness followed by Structur 3, Protemp 4 and Dencor groups. After polishing and simulated brushing, Filtek Z350XT groups also presented the lowest roughness values, followed by bis-acryl groups (Structur 3 and Protemp 4) and Dencor groups demonstrated the highest surface roughness. Sof-Lex Pop-On discs system exhibited lower roughness values for all groups. CONCLUSIONS: Sof-Lex Pop-On discs system promoted the best polishing for all groups. Overall, Filtek Z350XT groups presented lower results for both roughness and wear for all periods evaluated, followed by Protemp 4 and Structur 3, meanwhile Dencor groups presented the highest roughness and wear values for all periods. Key words:Acrylic resin, bis-acryl, brushing, composite resin, polishing, roughness, wear.

8.
Braz. dent. sci ; 25(1): 1-9, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1361885

RESUMO

Objetivo: O objetivo foi avaliar a resistência de união de seis adesivos experimentais contendo sistemas fotoiniciadores binários ou ternários, associados a três diferentes concentrações de MDP (0-12% em peso) após 12 meses de armazenamento em água destilada. Material e Métodos: Adesivos experimentais foram preparados com: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT e etanol, contendo sistemas fotoiniciadores binários (CQ/amina) ou ternários (CQ/amina/DPIHFP ­ 0,5% em peso). Foi adicionado a esta composição 0%, 6% ou 12% em peso de MDP. Os sistemas adesivos foram aplicados seguindo o protocolo com condicionamento ácido. Moldes cilíndricos transparentes foram colocados sobre a dentina hibridizada, preenchidos com resina composta e fotopolimerizados. Os corpos-de-prova foram armazenados em água destilada a 37oC por 24h ou 12 meses e submetidos ao ensaio de microcisalhamento (n=6). Os dados foram analisados por ANOVA de três fatores e teste de Tukey (α=5%). Resultados: Para o sistema binário, após 12 meses de armazenamento, todos os valores de resistência de união foram semelhantes. Em relação à degradação da resistência de adesão ao longo do tempo, as formulações de MDP de 6% e 12% mostraram resistência de união mais estável do que 0% de MDP. Para o sistema ternário, todas as formulações (0%, 6% e 12% em massa de MDP) mostraram resistência de união estável em função do tempo. Conclusão: Para o sistema binário, as concentrações de 6 e 12% em massa de MDP foram capazes de manter a resistência de união em função do tempo, enquanto que para o sistema ternário, a estabilidade de união foi obtida independentemente da concentração de MDP. Pode-se concluir que, para a formulação dos adesivos utilizados neste estudo, independente do sistema fotoiniciador, a concentração de 12% MDP apresentou valores de resistência de união mais estáveis após 12 meses de armazenamento em água (AU)


Objective: The aim was to evaluate the bond strength of six experimental adhesives containing binary or ternary photoinitiator systems, associated with three different MDP concentrations (0-12wt%) after 12 months of storage in distilled water. Material and Methods: Experimental adhesives were prepared with: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT, and ethanol, containing binary (CQ/amine) or ternary (CQ/amine/DPIHFP (diphenyliodonium hexafluorophosphate) ­ 0.5wt%) photoinitiator systems. It was added to this composition 0wt%, 6wt%, or 12wt% of MDP. The adhesive systems were applied following the etch-and-rinse protocol. Transparent cylindrical molds were placed on the hybridized dentin, filled with composite resin and light-cured. The specimens were stored in distilled water at 37oC for 24h or 12 months and submitted to a microshear bond strength test (n=6). Data were analyzed by three-way ANOVA and Tukey's test (α=5%). Results: For the binary system, after 12 months of storage, all bond strength values were similar. Regarding bond strength degradation over time, 6wt% and 12wt% MDP formulations showed more stable bond strength than 0wt% MDP. For the ternary system, all formulations (0wt%, 6wt% and 12wt%) showed stable bond strength over time. Conclusion: For the binary photoinitiator system, the 6wt% and 12wt% MDP concentrations were able to keep bond strength stable over time, while for the ternary system, bond strength stability was achieved regardless the MDP concentration. (AU)


Assuntos
Cimentos Dentários , Fotoiniciadores Dentários
9.
Dent Mater ; 36(12): 1544-1556, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33012518

RESUMO

OBJECTIVE: To evaluate the influence of the addition of functionalized and non-functionalized TiO2 nanostructures on properties of a resin composite. METHODS: TiO2 nanostructures were synthesized and functionalized, using 3-(aminopropyl)triethoxysilane (APTMS) and 3-(trimethoxysilyl)propyl methacrylate (TSMPM). Characterizations were performed with XRD, EDS, TEM, and TGA. Resin composites containing Bis-GMA/TEGDMA, CQ, DABE, and barium-aluminum silicate glass were produced according to TiO2 nanostructure (nanotube or nanoparticle), concentration (0.3 or 0.9 wt%), and functionalization (APTMS or TSMPM). The resin composite without nanostructures was used as control. The amount of fillers was kept constant at 78.3 wt% for all materials. The degree of conversion (DC - at 0 h and 24 h), maximum polymerization rate (Rpmax), and Knoop microhardness (KHN before and after ethanol softening) were evaluated. Data were analyzed with two-way ANOVA with repeated measures and Tukey's HSD (α = 0.05). RESULTS: TGA results demonstrated that functionalizations were effective for both nanostructures. For DC, resin composites, time and interaction effect were significant (p < 0.001). Higher DC was found for 0.3-wt%-functionalized-nanotubes at 24 h. For nanoparticles, only 0.9-wt%-non-functionalized and 0.3-wt%-APTMS-functionalized showed DC similar to the control and all other groups showed higher DC (p < 0.05). Rpmax was higher for 0.3-wt%-APTMS-nanotubes, which corresponded to higher DC after 24 h. The lowest Rpmax occurred for 0.9-wt%-TSMPM-nanotubes, which showed smaller DC at 0 h. For KHN, resin composites, ethanol softening and interaction effect were significant (p < 0.001). KHN decreased after ethanol softening all groups, except for 0.3-wt%-TSMPM-nanotubes, 0.9-wt%-TSMPM-nanotubes, and 0.3-wt%-non-functionalized-nanoparticles. CONCLUSION: The resin with 0.3-wt%-TSMPM-nanotubes showed higher DC after 24 h, while being the most stable material after the ethanol softening. SIGNIFICANCE: The addition of functionalized TiO2 nanostructures in resin-based materials may improve the properties of the material.


Assuntos
Nanopartículas , Nanotubos , Bis-Fenol A-Glicidil Metacrilato , Resinas Compostas , Teste de Materiais , Metacrilatos , Polietilenoglicóis , Ácidos Polimetacrílicos , Propriedades de Superfície , Titânio
10.
Braz Oral Res ; 34: e105, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32876118

RESUMO

The aim of this research was to evaluate the influence of MDP (10-methacryloyloxydecyl dihydrogen phosphate) concentration and application mode of experimental adhesives on microshear bond strength (µSBS) to dentin after storage in distilled water at 37°C for 24h and 6 months. Five experimental adhesives were prepared with: CQ, DABE, BHT, ethanol, HEMA, TEGDMA, Bis-EMA, UDMA, and Bis-GMA. Concentrations of 0 wt%, 3 wt%, 9 wt%, 12 wt% or 15 wt% of MDP were added to their composition. The adhesives were applied to flat dentin surfaces in etch-and-rinse or self-etching modes. Cylindrical molds filled with light-cured composite resin were placed above the dentin. The specimens were stored in distilled water at 37oC for 24h or 6 months and submitted to µSBS testing. The adhesives were also submitted to pH analysis. The data were analyzed by one-way ANOVA, three-way ANOVA and Tukey's test (α = 5%). All the adhesives used in the etch-and-rinse mode showed significantly higher bond strength than the adhesives applied in the self-etching approach. The 9 wt% adhesive showed the highest bond strength values, and 3 wt% was most stable after storage. A strong negative correlation between MDP concentration and pH was observed. It was concluded that the formulations with low concentrations of MDP (up to 9 wt%) showed better results for bond strength and bond strength degradation over time.


Assuntos
Colagem Dentária , Adesividade , Resinas Compostas , Cimentos Dentários , Dentina , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência à Tração
11.
J Prosthodont Res ; 64(4): 408-416, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32059955

RESUMO

PURPOSE: To evaluate the shear bond strength (SBS) between Y-TZP and a resin luting agent, after 1 of 2 enhancing strategies with TiO2--nts was applied, either to the resin luting agent or the Y-TZP mass, in different concentrations. METHODS: In the Strategy TiO2-nts on ceramic, the resin luting agent Panavia F2.0™ (Kuraray) and an experimental Y-TZP with added concentrations of TiO2--nts (0%, 1%, 2%, and 5% vol/vol) and a commercial Y-TZP, comprised 5 different groups (n = 10). In the Strategy TiO2-nts on cement, the resin luting agent RelyX U200™ (3 M ESPE) was added with different concentrations of TiO2--nts (0%, 0.3%, 0.6%, 0.9% wt/wt) luted to a commercial Y-TZP, comprising 4 different groups (n = 10). The Y-TZP discs were included in acrylic bases, and a cylinder (3 × 3 mm) of the correspondent luting agent for each respective group was applied over them. After 24 h, specimens were subjected to SBS assessments in a universal testing machine. Field emission scanning electron microscopy and energy dispersive X-ray spectroscopy analyses were also performed on Y-TZP surfaces. Data were analyzed via analysis of variance and Tukey tests (α = 0.05). RESULTS: TiO2-nts on ceramic influenced the bond strength significantly, but not linearly; TiO2-nts on cement did not influence bond strength when analyzed separately, nor in comparison with the first. CONCLUSION: Y-TZP enhancements with TiO2-nts led to a higher SBS with Panavia F2.0, a 5% TiO2--nt concentration presented the highest bond strength. Modified Rely X U200 did not improve SBS.


Assuntos
Colagem Dentária , Nanotubos , Cimentos Dentários , Análise do Estresse Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície , Titânio , Ítrio , Zircônio
12.
Braz. oral res. (Online) ; 34: e105, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132706

RESUMO

Abstract The aim of this research was to evaluate the influence of MDP (10-methacryloyloxydecyl dihydrogen phosphate) concentration and application mode of experimental adhesives on microshear bond strength (μSBS) to dentin after storage in distilled water at 37°C for 24h and 6 months. Five experimental adhesives were prepared with: CQ, DABE, BHT, ethanol, HEMA, TEGDMA, Bis-EMA, UDMA, and Bis-GMA. Concentrations of 0 wt%, 3 wt%, 9 wt%, 12 wt% or 15 wt% of MDP were added to their composition. The adhesives were applied to flat dentin surfaces in etch-and-rinse or self-etching modes. Cylindrical molds filled with light-cured composite resin were placed above the dentin. The specimens were stored in distilled water at 37oC for 24h or 6 months and submitted to μSBS testing. The adhesives were also submitted to pH analysis. The data were analyzed by one-way ANOVA, three-way ANOVA and Tukey's test (α = 5%). All the adhesives used in the etch-and-rinse mode showed significantly higher bond strength than the adhesives applied in the self-etching approach. The 9 wt% adhesive showed the highest bond strength values, and 3 wt% was most stable after storage. A strong negative correlation between MDP concentration and pH was observed. It was concluded that the formulations with low concentrations of MDP (up to 9 wt%) showed better results for bond strength and bond strength degradation over time.


Assuntos
Colagem Dentária , Resistência à Tração , Teste de Materiais , Adesividade , Adesivos Dentinários , Resinas Compostas , Cimentos de Resina , Cimentos Dentários , Dentina
13.
Braz. j. oral sci ; 19: e201674, jan.-dez. 2020. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1116258

RESUMO

Aim: To evaluate the color stability of bovine enamel with artificial white spot lesions treated with resin infiltration (ICON) or remineralization with fluoride using two storage methods. Methods: Sixty incisors were submitted to artificial white spot lesion induced by demineralization-remineralization (DE-RE) cycling. Initial color was evaluated with CIE-Lab to measure ΔEab. Demineralized teeth were divided according to the treatment of the white spot lesion (n = 20): 1) Remineralization with 2% neutral fluoride gel for 4min (control); 2) ICON application following manufacturer's recommendations; and 3) ICON with decreased drying time after the application of ethanol. After 24h, color was evaluated and samples were subdivided (n = 10) according to storage: 1) distilled water for 1 month; 2) grape juice for 10min daily. After storage, color was evaluated. L*, a* and b* data were analyzed by one-way ANOVA and ∆Eab data by two-way ANOVA followed by Tukey's HSD (α = 0.05). Results: L* was affected by juice storage, and decreased when ICON was applied with decreased drying time after the ethanol application. The same behavior occurred with a* (increase with reduced drying time), while b* was not affected. For ∆Eab significant differences were observed between groups (p = 0.0219) and storage methods (p = 0.0007). There was no interaction effect (p = 0.1118). Remineralization with fluoride presented the lowest color changes after storage in water. Conclusion: Treatment of artificial carious lesions with resin infiltration presented greater color changes than fluoride remineralization after storage in both solutions in vitro


Assuntos
Cárie Dentária , Esmalte Dentário , Estética Dentária
14.
Braz Dent J ; 30(6): 592-598, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31800754

RESUMO

This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.


Assuntos
Resinas Compostas , Teste de Materiais , Polimerização , Viscosidade
15.
Braz. dent. j ; 30(6): 592-598, Nov.-Dec. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055449

RESUMO

Abstract This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.


Resumo O presente estudo teve como objetivo avaliar as propriedades de polimerização de materiais bulk-fill (baixa e alta viscosidade) utilizando luz contínua de alta intensidade e fotoativação intermitente em relação ao estresse de contração de polimerização e grau de conversão (DC). As seguintes resinas compostas Bulk-fill e nanohíbridas convencionais foram avaliadas: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) e Filtek Bulk Fill Posterior (3M/ESPE). Um dispositivo de LED (DB 685, Dabi Atlante) foi utilizado nos dois protocolos: fotoativação contínua e intermitente contínua (ciclos de liga e desliga) com exposição idêntica (14 J/cm2). A tensão de contração de polimerização (n=6) foi avaliada através da inserção de um incremento único de 12 mm3 entre duas placas de aço inoxidável (6×2 mm) adaptadas a uma Máquina de Ensaio Universal (UTM), em tempos diferentes. As medições foram registradas após a fotoativação. O grau de conversão foi avaliado por FTIR-ATR (n=5). Os dados foram analisados ​​pelos testes ANOVA a três fatores e teste de Tukey (α=0,05). A resina Bulk Fill Posterior apresentou maiores valores de tensão de contração quando fotoativadas com a técnica intermitente (p<0,05). A fotoativação intermitente aumentou o grau de conversão nas resinas bulk-fill de baixa viscosidade (p<0,05). Portanto, o uso de fotoativação modulada (intermitente) deve ser indicado com cautela, uma vez que seu uso pode influenciar a tensão de contração e o grau de conversão dos compósitos, o que varia de acordo com as formulações da resina.


Assuntos
Teste de Materiais , Resinas Compostas , Viscosidade , Polimerização
16.
J Appl Oral Sci ; 27: e20180631, 2019 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-31411263

RESUMO

OBJECTIVE: Extensive restorations in posterior teeth always bring doubts to the clinicians regarding the best protocol, mainly when structures of reinforcement were lost. OBJECTIVE: This study aimed to evaluate the effect of beveling on the fracture resistance and pattern of class II (MOD) restored teeth. METHODOLOGY: Ninety human premolars were randomly assigned into 9 groups: CTR (control/sound); NC (cavity preparation, non-restored); RU (restored, unbeveled); RTB (restored, entire angle beveling); RPB (restored, partial/occlusal beveling); EC (endodontic access/EA, non-restored); EU (EA, unbeveled); ETB (EA, entire angle beveling); EPB (EA, partial/occlusal beveling). Teeth were restored with Esthet X resin composite and stored in distilled water for 24 h before the inclusion in PVC cylinders. The axial loading tests were performed with 500 kgF at 0.5 mm/min crosshead speed until fracture of the specimens. Fracture resistance and pattern were accessed and data were analyzed using one-way ANOVA and Tukey's HSD test (α=0.05). RESULTS: Mean (±SD) failure loads ranged from 136.56 (11.62) to 174.04 (43.5) kgF in the groups tested without endodontic access. For endodontically accessed teeth, fracture resistance ranged from 95.54 (13.05) to 126.51 (19.88) kgF. Beveling of the cavosurface angle promoted the highest fracture resistance values (p<0.05) and prevented catastrophic fractures. CONCLUSIONS: Cavosurface angle beveling is capable of improving fracture resistance and pattern for both endodonticaly accessed and non-accessed teeth.


Assuntos
Dente Pré-Molar , Preparo da Cavidade Dentária/métodos , Restauração Dentária Permanente/métodos , Análise de Variância , Resinas Compostas/uso terapêutico , Humanos , Distribuição Aleatória , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Risco , Fraturas dos Dentes , Dente não Vital , Resultado do Tratamento
17.
J Appl Oral Sci ; 27: e20180449, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30994777

RESUMO

OBJECTIVE: This study aims to evaluate the effect of sonochemical treatment on the surface of yttria-stabilized tetragonal zirconia (Y-TZP) before and after the final sintering. MATERIAL AND METHODS: Twenty-eight Y-TZP discs were divided into four groups (n=7), according to surface treatment: PRE: pre-sintering sonication with 30% nominal power for 15 min; POS: post-sintering sonication with 30% nominal power for 15 min; JAT: air abrasion with 50-µm alumina particles; and CON: control group with no treatment. The POS and JAT groups were sintered before sonication and the PRE group after sonication. Surface roughness was analyzed using confocal microscopy, after which resin cement cylinders were placed on the surface of the Y-TZP discs and subjected to mechanical microshear bond strength test until fracture. Surface roughness and microshear bond strength values underwent ANOVA and the Tukey tests. RESULTS: The surface roughness values for the PRE group (299.91 nm) and the POS group (291.23 nm) were not significantly different (p≥0.05), statistically, and the surface roughness value of the JAT group (925.21 nm) was higher than those of PRE and POS (p=0.007) groups. The mechanical microshear bond strength test showed that there was no statistically significant difference between the groups (p=0.08). CONCLUSIONS: Therefore, the results showed that sonochemical treatment modifies the Y-TZP surface and is similar to the well-established sandblasting surface treatment regarding the strength of the bond with the resin cement.


Assuntos
Colagem Dentária/métodos , Cimentos de Resina/química , Ítrio/química , Zircônio/química , Abrasão Dental por Ar , Análise de Variância , Teste de Materiais , Valores de Referência , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Estatísticas não Paramétricas , Propriedades de Superfície
18.
Braz Oral Res ; 33: e015, 2019 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-30758411

RESUMO

We assessed the effect of a new coating material based on resin-modified glass-ionomer with calcium (Ca) in inhibiting the demineralization of underlying and adjacent areas surrounding caries-like lesions in enamel. The measures used were surface hardness (SH) and cross-sectional hardness (CSH). Thirty-six bovine enamel specimens (3 × 6 × 2 mm) were randomly allocated into three groups (n = 12): No treatment (NT); resin-modified glass-ionomer with Ca (Clinpro XT Varnish, 3M ESPE) (CL), and fluoride varnish (Duraphat, Colgate) (DU). The specimens were subjected to alternated immersions in demineralizing (6 h) and remineralizing solutions (18 h) for 7 days. SH measurements were conducted at standard distances of 150, 300, and 450 µm from the treatment area. CSH evaluated the mean hardness profile over the depth of the enamel surface and at standard distances from the materials. The energy-dispersive X-ray spectroscopy analysis was conducted to evaluate the demineralization bands created on the sublayer by % of calcium (Ca), phosphorus (P), and fluoride (F). Ca/P weight ratio was also calculated. Based on SH and CSH measurements, there was no difference between groups at the distances 150 µm (p = 0.882), 300 µm (p = 0.995), and 450 µm (p = 0.998). Up to 50 µm depth (at 150 µm from the treatment area), CL showed better performance than DU ( p< 0.05). NT presented higher loss of Ca and P than CL and DU (p < 0.05). There was no significant difference in the % of F ion among the three groups. The new coating material was similar to F varnish in attenuating enamel demineralization.


Assuntos
Cálcio/química , Esmalte Dentário/efeitos dos fármacos , Cimentos de Ionômeros de Vidro/química , Cimentos de Resina/química , Desmineralização do Dente/prevenção & controle , Animais , Cariostáticos/química , Bovinos , Fluoretos Tópicos/química , Testes de Dureza , Concentração de Íons de Hidrogênio , Teste de Materiais , Distribuição Aleatória , Valores de Referência , Reprodutibilidade dos Testes , Fluoreto de Sódio/química , Espectrometria por Raios X , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo
19.
J Appl Oral Sci ; 27: e20180132, 2019 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-30624465

RESUMO

Bulk-fill composites were introduced in dentistry to accelerate clinical procedures while providing adequate outcomes. Concerns regarding the use of bigger composite increments rely on the polymerization shrinkage and shrinkage stress, which may generate gaps on the adhesive interface and result in a reduced success rate. OBJECTIVE: To evaluate the polymerization shrinkage stress of different bulk-fill resin composites and their elastic modulus. MATERIALS AND METHODS: Fourteen specimens were made for each of the nine different resin composites (seven with 12 mm3 and seven with 24 mm3): Surefill SDR flow (SDR), X-tra Base (XB), Filtek Bulk Fill Flowable (FBF), Filtek Z350XT Flow (Z3F); Tetric Evo Ceram Bulk Fill (TBF), X-tra Fil (XF), Filtek Bulk Fill (FBP), Admira Xtra Fusion (ADM) and Filtek Z350 XT (Z3XT). Linear shrinkage stress was evaluated for 300 s with the aid of a linear shrinkage device adapted to a Universal Testing Machine. For each composite group, seven additional specimens (2x2x25 mm) were made and Young's modulus was evaluated with a 3-point bending device adapted in a Universal Testing Machine with 0.5 mm/min crosshead speed and 50 KgF loading cell. RESULTS: For 12 mm3 specimens, three-way ANOVA showed that only SDR and TBF generated lower stress after 20 s. Considering 300 s, TBF, SDR, and XF generated the lowest stress, followed by ADM, FBP, XB, and FBF, which were similar to Z3XT. Z3F generated the highest stress values for all time points. Considering 24 mm3 specimens after 20 s, all bulk fill composites generated lower stress than Z3XT, except XB. After 300 s, SDR, FBP, and ADM generated the lowest stress, followed by TBF and XF. For elastic modulus, one-way ANOVA showed that FBF, SDR, Z3F, and ADM presented the lowest values, followed by XB and TBF. FBP, Z3XT, and XF presented the highest elastic modulus among the evaluated composites. CONCLUSIONS: Bulk-fill resin composites presented equal to lower shrinkage stress generation when compared to conventional composites, especially when bigger increments were evaluated. Bulk-fill composites showed a wide range of elastic modulus values, but usually similar to "regular" composites.


Assuntos
Resinas Compostas/química , Módulo de Elasticidade , Polimerização , Estresse Mecânico , Análise de Variância , Análise do Estresse Dentário , Teste de Materiais , Metacrilatos/química , Valores de Referência , Reprodutibilidade dos Testes , Siloxanas/química , Estatísticas não Paramétricas , Propriedades de Superfície
20.
Gen Dent ; 67(1): 47-50, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30644831

RESUMO

Zirconia-reinforced lithium silicate (ZLS) has recently been introduced in an effort to improve the mechanical properties of glass-ceramic materials. In vitro evaluations suggest that this class of material has high flexural strength and exhibits satisfactory adhesion to resin cement and wear resistance. Since few clinical reports of this novel material are currently available, the aim of this case report is to describe clinical perceptions regarding the handling and performance of ZLS ceramics when used for laminate veneers on the maxillary incisors.


Assuntos
Cerâmica/química , Porcelana Dentária , Lítio , Silicatos/química , Zircônio/química , Colagem Dentária/métodos , Seguimentos , Humanos , Lítio/química , Teste de Materiais , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...